The technical case for reusable healthcare interoperability, and how to measure whether your FHIR investment is paying off.
A FHIR endpoint can pass its launch demonstration while engineers continue rebuilding transformations for each application. Before leadership calls the standard a failure, it should examine what the project left behind for the next team: validated mappings, executable tests, documented API behavior, and an owner responsible for maintaining them.
At Brandywine Consulting Partners, we believe FHIR deserves a serious, sustained commitment. Healthcare needs a practical way to carry integration knowledge forward: agreed clinical definitions, documented API behavior, validated mappings, and tests that survive the original project team. FHIR provides important building blocks for that work. Organizations still have to implement and maintain them.
The strongest case for FHIR becomes visible over time. A second application should inherit useful work from the first. A new data source should have a defined path into an established exchange model. A vendor upgrade should trigger a known set of compatibility tests. These are achievable engineering objectives, and leaders should fund and measure them.
We should also expect more than connectivity. Clinicians need information they can interpret in context. Patients need access that helps them participate in their care. Developers need a dependable foundation on which to build. Giving FHIR a fair trial means evaluating how well an implementation serves those needs, including the work that continues after an endpoint goes live.
Key takeaways
- ▸The infrastructure is already there. ONC reported that 93% of hospitals had implemented FHIR-based APIs in 2024, up from 84% in 2019. That is deployed capability, not proof of clinical accuracy, active use or better outcomes.
- ▸Convergence needs a versioned agreement. Name the FHIR release, US Core and implementation guide versions, required profiles, searches, operations and authorization flows. "Supports US Core" needs a stated scope.
- ▸Must Support is not "always populated." In US Core it assigns producer and consumer responsibilities; missing and suppressed data have distinct rules your application must handle.
- ▸Schema-valid can still be clinically wrong. A unit relabeled without conversion passes structural validation. Acceptance needs terminology, reference, timing and workflow evidence reviewed with clinicians.
- ▸The reusable asset is mapping + rationale + tests. Judge the program by what the second integration reuses from the first, and who owns those assets afterward.
- ▸Contain local differences in architecture. Source adapters, a governed transformation layer and stable consumer contracts, verified by contract tests after every vendor or mapping change.
- ▸Empty is not negative. SMART on FHIR permits searches to omit results for permission reasons; an absent Condition is not proof the patient lacks it.
A substantial foundation already exists
FHIR is already part of a substantial installed base. In a February 2026 presentation, ONC reported that 93% of hospitals had implemented FHIR-based APIs in 2024, compared with 84% in 2019. The analysis used hospital Promoting Interoperability technology reporting and the Certified Health IT Product List. This is evidence of deployed capability; it does not establish clinical accuracy, active use, or improved outcomes. [1]
That distinction should sharpen our investment decisions. There is infrastructure to build on, and there is work remaining to make it useful. Organizations that have paid for access to an API have good reason to evaluate what additional value they can obtain from it.
What is FHIR? FHIR, or Fast Healthcare Interoperability Resources, defines healthcare information models and methods for exchanging them. Resources such as Patient, Observation, and DiagnosticReport provide common structures. Profiles constrain those structures for a particular context. Standard API interactions give implementers shared expectations for accessing and exchanging information. [2]
The opportunity is cumulative. Teams can retain a resource contract, improve its mapping rules, expand its test coverage, and use that work again. That makes interoperability an engineering capability worth maintaining across projects.
US Core gives convergence a concrete form
The question we hear in discussions about FHIR is reasonable: are organizations converging on common implementation guides, or are local variations preserving the same duplication?
We see a credible foundation for convergence, with considerable implementation work still ahead. US Core defines a common baseline for clinical content and minimum exchange behavior in the United States. It distinguishes support for profiles from support for profiles together with their specified interactions. A statement that a system supports US Core therefore needs an accompanying description of scope. [3]
Federal API certification adds repeatable testing. The Inferno certification test kit covers areas including US Core profiles, required searches, references, SMART authorization, and Bulk Data. It also accommodates approved standards versions. Certified systems can consequently share a foundation while differing in their supported version combinations. [4]
For an implementation team, the practical answer is to establish a versioned agreement. Name the applicable FHIR release and implementation guide versions. Identify the required profiles, searches, operations, and authorization flows. Document the workflow that the receiving application needs to complete.
Pay close attention to the meaning of Must Support. In US Core, this designation establishes responsibilities for producing and processing data; it does not mean that every optional element will contain a value in every response. Mandatory presence, missing information, and suppressed information have distinct rules. [5]
Those distinctions affect application design. A receiving team should know which fields it can expect, how it will handle absence, and when it needs further investigation. Agreement on those details reduces ambiguity before engineers turn it into application-specific workarounds.
Convergence also requires restraint. We recommend checking whether an existing profile or extension can meet the need before creating a local alternative. When a local difference is necessary, document its purpose and preserve the meaning that other consumers already understand. Feed recurring problems back to the relevant standards community with reproducible examples.
Clinical meaning must survive the transformation
A result can be structurally valid and still describe the wrong clinical reality.
An Observation can pass schema validation and still describe the wrong clinical reality. A transformation may attach a result to the wrong patient, substitute the processing timestamp for the clinical event time, or relabel a quantity without converting its value.
HL7's validation guidance distinguishes structural checks, terminology bindings, profile constraints, and external business rules. It also states that computable validation is incomplete and that static resource testing cannot establish full conformance. Automated validation provides essential evidence within that scope. [6]
Consider a hypothetical laboratory interface. The source reports a hemoglobin concentration in grams per liter. A transformation changes the unit label to grams per deciliter but leaves the numeric value unchanged. The output can contain a valid numeric field and a recognizable unit while misrepresenting the source measurement by a factor of ten. Detecting that error requires a comparison of the source and transformed meaning, including the conversion rule. FHIR's Observation model provides fields for the result, units, subject, clinical timing, and other context that make such checks possible. [7]
For that workflow, we would require evidence at several levels:
| Validation concern | Evidence we would expect |
|---|---|
| Resource structure | The output satisfies the agreed profile and its constraints. |
| Terminology and quantity | The selected concept represents the source observation; any unit conversion preserves the quantity. |
| Patient and references | The subject association is correct, and linked resources refer to the intended records. |
| Time and status | Clinical timing remains distinct from ingestion timing; corrections and result status retain their meaning. |
| Receiving workflow | The application displays, interprets, and updates the information as intended. |
A generic FHIR validator covers only part of this acceptance model. Clinical reviewers and source-system specialists must help define the expected results.
The reusable asset is the combination of the mapping, its rationale, and its tests. Once a team has resolved a local laboratory code and validated the transformation, another application should be able to benefit from that decision. A correction should improve the shared transformation and its regression tests, with controlled rollout to affected consumers.
This is why we argue for investment in semantics. FHIR gives teams a common structure in which to express the answer. Good engineering makes that answer faithful to the source and useful to the recipient. Our article on the AI-native EHR data pollution problem makes the same point from the AI side.
The second integration should inherit the first
Mapping decisions made once should not have to be rediscovered by the next team.
Consider another illustrative scenario. An organization connects three clinical systems to a care-management application. Engineers reconcile local identifiers, establish terminology mappings, and define how to represent corrected results. Later, an analytics team needs the same underlying information.
If the first project's transformations live inside application-specific code, the analytics team may have to rediscover much of that work. If the organization instead maintains governed mappings into agreed FHIR profiles, the second team can reuse those mappings and the evidence supporting them. It will still need appropriate permissions, analytics transformations, and acceptance testing for its own purpose.
The economic opportunity comes from reducing repeated decisions and concentrating maintenance in assets that multiple consumers use. The first implementation may require more investment because the team is establishing contracts, tests, and operational tooling. A credible business case should account for that cost and identify which later uses will benefit.
The value extends to future migrations. If a source-system replacement can be handled through a revised adapter while validated consumer contracts remain stable, the organization can limit how much downstream software it must revisit. That flexibility belongs in the business case alongside implementation cost.
Reuse also has a limit. A local concept that carries additional clinical meaning should not be flattened to make a common model look tidy. Preserve necessary context and document extensions or information that cannot be represented adequately. Shared implementation should reduce avoidable variation while retaining meaningful distinctions.
This changes the question leaders ask at project review. Alongside delivery cost and launch date, ask which mappings, tests, and API contracts the next project can use. Ask who owns them after the current team moves on. Budget for maintaining those assets through source-system and standards changes.
We would judge the long-term investment by the amount of useful work it preserves and the reliability of the workflows built on it. A rising endpoint count alone gives leadership little evidence of either.
Build an architecture that contains local differences
Our recommended pattern separates source-specific integration work from the contracts that consuming applications use. Its boundaries should reflect the organization's data ownership, latency, and retention requirements.
Source adapters, a governed transformation layer and stable consumer contracts, tied together by tests.
At the source boundary, adapters handle local formats and identifiers. A governed transformation layer applies approved mappings, resolves references, and records exceptions. Consumers use agreed FHIR profiles and interactions through an authorized service. Teams maintain compatibility tests across those boundaries so a change in one source does not silently alter downstream meaning.
For this pattern, we would evaluate a FHIR repository where persistence is useful and a FHIR interface over existing systems. The choice should follow requirements for search, performance, consistency, and data ownership.
| Design | Strengths | Responsibilities it creates |
|---|---|---|
| FHIR facade over source systems | Avoids some data duplication | Depends on source availability and response time; any caching or staging adds freshness and reconciliation work |
| FHIR repository | Supports consolidated access and search | Refresh, reconciliation, retention and deletion |
Teams need to understand what the data represents in each design.
On Azure, the FHIR service in Azure Health Data Services is one managed platform option for persisting and exchanging FHIR resources. [8] We would place that choice within a wider design covering identity, network controls, application authorization, observability, recovery, and source integration. Selecting a managed service does not complete that design; see our Azure hosting practice for how we approach the surrounding platform.
The interface agreement should also be verifiable. A server's CapabilityStatement describes capabilities or requirements, depending on its purpose. It is useful evidence, but it cannot capture every interoperability-relevant variation. [9] We recommend checking the deployed endpoint against its advertised behavior: required search combinations, pagination, returned references, error responses, and access restrictions.
A contract test suite should make those expectations executable. Teams can then rerun it after vendor upgrades, mapping changes, or configuration changes and identify which consumers need attention.
Preserve useful existing systems while improving access
Organizations do not have to replace every functioning interface to benefit from FHIR. A reliable HL7 v2 feed can remain an upstream source while a governed transformation exposes appropriate resources for additional consumers.
HL7 publishes v2-to-FHIR mapping guidance, including dependencies and cases where differences between the models require implementation decisions. C-CDA mapping guidance also documents gaps and known issues. These are useful starting points for modernization, with local validation still required. [10] [11]
We recommend preserving the source evidence needed to investigate a transformation, including the original document where appropriate. Teams should document information loss and unresolved ambiguity rather than silently manufacture precision.
The same discipline applies to payer transactions. Da Vinci Prior Authorization Support describes FHIR exchanges alongside conversion to and from X12 when required for the transaction context. [12] A FHIR implementation must account for the applicable payer, intermediary, and transaction requirements. An endpoint alone does not replace those obligations. Our X12 to FHIR mapping guide covers that boundary in more detail.
This gives organizations a practical migration strategy. Select a useful clinical workflow, establish the common contract, and extend access without forcing an unrelated replacement of systems that already perform their jobs. Expand when the implementation demonstrates value and the operating team can support it.
The value extends into applications, analytics, and AI
More reusable application access
SMART on FHIR provides standardized authorization patterns and scopes tied to FHIR resources. Those scopes remain subject to underlying access policies. The specification explicitly allows a successful search response to omit results because of permissions. [13]
That creates an important application requirement: an empty or partial response must not automatically become a clinical conclusion. A care-management application should not interpret an absent Condition as proof that a patient does not have that condition. Its designers need to understand the scope and limits of the information available to them.
Shared authorization patterns can reduce bespoke implementation work. Organizations still need to configure and test access decisions, including consent and restrictions where applicable. FHIR itself is not a complete security system. [14]
We would test allowed, denied, and filtered scenarios alongside the successful workflow. We would also ensure that operational telemetry supports investigation without exposing clinical payloads in unrestricted logs. The objective is dependable, appropriate access that application teams can build on.
A common mechanism for population data
FHIR Bulk Data defines asynchronous export, status polling, and files using newline-delimited JSON. Its scope includes large datasets; it does not solve real-time exchange, patient matching, or downstream transformation. Its _since parameter concerns changes to resources, which can differ from the dates of the underlying clinical events. [15]
For analytics, that provides a reusable extraction mechanism. The receiving team still needs checkpoints, deduplication, reconciliation, and a defined approach to corrections and deletions. Those controls should reflect the behavior of the actual server and export version. Confirm how the server reports deletions: the Bulk Data guide permits the deleted-resource manifest entry to be omitted in some circumstances. [15]
A shared clinical exchange model can make it easier to connect new analytics uses to known inputs. It will not define a quality measure, choose a risk-model cohort, or resolve an ambiguous business rule. The benefit is a more consistent starting point for that work, with fewer source-specific interpretations embedded in each report or model.
Better traceability for data used by AI
Lineage lets reviewers trace an AI result back to the source and the mapping version behind it.
FHIR's Provenance resource can describe the activities and agents involved in producing or changing a resource. AuditEvent addresses system activity such as access. These records support investigation; their presence does not establish that the underlying clinical assertion is true. [16]
For AI workflows, we recommend retaining source identifiers and transformation lineage, including which version of the mapping produced an input. Keep model-generated assertions distinguishable from source observations, and define how reviewers can trace a result back to its evidence.
This is a practical connection between interoperability and AI governance. Teams with documented data meaning and lineage are better positioned to investigate a questionable model result, assess a source-system change, and reproduce an evaluation. Model validation, bias assessment, and clinical oversight remain separate responsibilities.
Test the workflow that people depend on
FHIR can represent and exchange workflow information, but coordinated execution requires agreement about processes and responsibilities. HL7's workflow guidance makes that additional layer of agreement explicit. [17]
A prior authorization workflow, for example, needs more than a successful submission. The participants need to agree how to handle requests for additional information, pending decisions, corrections, and completion. They need a responsible party for exceptions. Retry behavior must avoid unintended duplicate actions, and the receiving application must show the state that its users need to act on.
Recent federal activity reinforces the value of this work. On November 12, 2026, ONC and CMS announced an electronic prior authorization testing initiative using production-like environments and 10–12-week testing sprints. It brings participants together around Da Vinci CRD, DTR, and PAS workflows. Participation is voluntary, and the agencies explicitly distinguish the testing from certification and compliance determinations. [18]
Our interpretation is that this is a useful model for implementation maturity: connect participants, exercise the complete workflow, and use observed failures to improve specifications and implementation guidance. Organizations can apply that discipline within their own trading-partner testing.
CMS-0057-F creates near-term API obligations for impacted payers, generally beginning January 1, 2027, with exact dates varying by payer type. These are distinct from operational provisions that generally began in 2026. The payer API obligations should not be read as a blanket requirement for every provider organization to build those APIs. [19] Our CMS-0057-F readiness article covers the release rehearsals in depth.
A deadline can justify the first investment. Leadership should also ask which durable capabilities that investment leaves behind for patient access, care coordination, and future exchange requirements.
Give FHIR an evaluation it can answer
Ask the steering committee what the second integration reused from the first.
We recommend a bounded implementation with a clear clinical or operational purpose, representative source data, and an identified receiving team. Agree the applicable profiles and versions before development. Establish expected clinical results and access behavior. Then test a second source or consumer to determine which work transfers.
This approach gives leadership evidence for an investment decision without assuming that a broad platform rollout will succeed. It also exposes dependencies early enough to address them.
Our proposed scorecard focuses on the work and outcomes that matter:
| Measure | What to examine |
|---|---|
| Time to a usable integration | Time from agreed requirements to successful execution of the intended workflow, including access and data acceptance. |
| Reuse on the next integration | Which mappings, tests, and contracts transfer unchanged; which require adaptation and why. |
| Semantic defects | Incorrect meaning found in reviewed records, measured against a defined sample and severity scale. |
| Operational reliability | Failed or delayed workflow completions, exception volume, and time to restore correct processing. |
| Change impact | Consumers affected by a source or profile change and the effort needed to validate the update. |
| User value | A workflow-specific measure such as reconciliation effort, missing-information follow-up, or time to obtain usable data. |
Establish a baseline and account for licensing, hosting, onboarding, mapping maintenance, security, and operational support when calculating value. Attribute improvements carefully when a wider workflow redesign contributes to the outcome.
Give the interoperability team authority to maintain the common contracts and resolve conflicting demands. Assign owners for clinical meaning and production exceptions. Preserve tests and implementation knowledge in shared repositories. A project can only demonstrate sustained reuse if someone remains responsible for sustaining it.
We are committed to FHIR because this work can improve what organizations are able to build next. A more consistent clinical foundation gives teams room to focus on useful applications and better access to information. That is a long-term opportunity worth pursuing with rigor.
We would put one question in front of the next interoperability steering committee: What did your second FHIR integration reuse from your first, and who was accountable for making that reuse possible?
Questions about FHIR implementation
Has FHIR failed if integrations still take months?
Not necessarily. Most hospitals already run FHIR-based APIs; slow integrations usually mean mappings, tests and API contracts were not retained or owned. Evaluate what the second integration reused from the first before judging the standard.
Does "supports US Core" guarantee two systems will interoperate?
No. US Core separates support for profiles from support for profiles plus their interactions, and certified systems can differ in version combinations. Agree a versioned scope: FHIR release, guide versions, profiles, searches, operations and authorization flows.
Is passing a FHIR validator enough to accept a transformation?
No. HL7 states that computable validation is incomplete. Structural validation will not catch a unit relabeled without conversion, a wrong patient reference, or a processing time substituted for clinical time. Acceptance also needs clinical and source-system review.
Should we replace our HL7 v2 interfaces with FHIR?
Not as a blanket rule. A reliable HL7 v2 feed can stay upstream while a governed transformation exposes FHIR resources to new consumers, using HL7's published v2-to-FHIR and C-CDA mapping guidance as a starting point with local validation.
FHIR facade or FHIR repository?
Choose by search, performance, consistency and data-ownership requirements. A facade avoids some duplication but depends on source availability; a repository supports consolidated access but adds refresh, reconciliation, retention and deletion responsibilities.
Give your next FHIR integration a head start
Brandywine Consulting Partners helps healthcare organizations assess, build, validate, and operate interoperability capabilities. Our work connects FHIR implementation with the architecture, data management, security, and ongoing support needed to make it useful. [20] [21] [22]
Our FHIR and integration services cover:
- ▸Readiness and architecture assessments: Review source systems, API capabilities, data availability, workflow requirements, and implementation dependencies; establish a practical roadmap.
- ▸FHIR APIs and reusable mappings: Develop resource mappings and API contracts, with HL7 v2, C-CDA, and X12 integration appropriate to the environment.
- ▸Clinical data quality and conformance: Assess US Core alignment, terminology, references, and transformation behavior; investigate gaps in the information consumers receive.
- ▸Security and cloud implementation: Design authorization, auditability, and Azure integration architectures around the intended users and data flows.
- ▸Testing and deployment: Apply conformance tools where appropriate, exercise workflows with partners, remediate defects, and plan controlled rollout.
- ▸Ongoing operations: Support monitoring, exception handling, change management, and the continued development of integration capabilities.
Start with one source-to-consumer workflow, the mappings you already have, and the failure your team keeps revisiting. BCP can help identify what is reusable, what needs remediation, and how to carry that work into subsequent integrations.
Bring us the integration you keep rebuilding. Let's give the next one a head start.
- ▸CMS-0057-F and the Cases Your 2027 Test Plan Must Survive: the release rehearsals that expose data-boundary and recovery gaps.
- ▸January 1, 2027 Is Not a FHIR Deadline. It Is a Workflow Deadline.: the CRD, DTR and PAS workflow behind the Prior Authorization API.
- ▸The AI-Native EHR Has a Permission Problem: why access scope shapes what any AI can safely see.
- ▸No Data at Rest: Designing a Healthcare Transaction Layer That Leaves No PHI Behind: payload retention boundaries and source-controlled retries.
References
Sources reviewed November 25, 2026. Standards versions, implementation requirements, and applicable regulatory obligations should be established for each project.
- ▸[1] ONC. Progress on Interoperability and Ongoing Improvements. February 11, 2026, slide 34. Hospital FHIR API adoption, 2019 and 2024. ↩
- ▸[2] HL7 International. FHIR R4 Overview for Architects. Resources, profiles and API interactions. ↩
- ▸[3] HL7 International. US Core Implementation Guide. Introduction and conformance scope. ↩
- ▸[4] ONC. Inferno ONC Certification (g)(10) Standardized API Test Kit. US Core, searches, SMART and Bulk Data testing. ↩
- ▸[5] HL7 International. US Core Must Support. Producer and consumer obligations; missing and suppressed data. ↩
- ▸[6] HL7 International. FHIR R4 Validating Resources. Scope and limits of computable validation. ↩
- ▸[7] HL7 International. FHIR R4 Observation. Value, units, subject and clinical timing. ↩
- ▸[8] Microsoft. What is the FHIR service in Azure Health Data Services. Managed FHIR platform option. ↩
- ▸[9] HL7 International. FHIR R4 CapabilityStatement. Declared server capabilities and their limits. ↩
- ▸[10] HL7 International. HL7 Version 2 to FHIR Mapping Guidelines. Mapping dependencies and model differences. ↩
- ▸[11] HL7 International. C-CDA on FHIR. Document mapping guidance, gaps and known issues. ↩
- ▸[12] HL7 International. Da Vinci Prior Authorization Support Conformance Details. FHIR exchange with X12 conversion where required. ↩
- ▸[13] HL7 International. SMART App Launch: Scopes and Launch Context. Scopes, access policy and filtered results. ↩
- ▸[14] HL7 International. FHIR R4 Security. Security responsibilities outside the standard. ↩
- ▸[15] HL7 International. Bulk Data Access: Export. Asynchronous export,
_sinceand deleted resources. ↩1 ↩2 - ▸[16] HL7 International. FHIR R4 Provenance. Provenance and AuditEvent. ↩
- ▸[17] HL7 International. FHIR R4 Workflow. Process agreements beyond resource exchange. ↩
- ▸[18] ONC. ONC and CMS Launch Industry Electronic Prior Authorization Testing Initiative. November 12, 2026. ↩
- ▸[19] Centers for Medicare & Medicaid Services. CMS Interoperability and Prior Authorization Final Rule (CMS-0057-F) Fact Sheet. Payer API requirements and timing. ↩
- ▸[20] Brandywine Consulting Partners. Integration Solutions. ↩
- ▸[21] Brandywine Consulting Partners. Consulting Services. ↩
- ▸[22] Brandywine Consulting Partners. CMS Interoperability and Prior Authorization Accelerator. ↩
Read online: www.brandywine.consulting/insights/fhir
© 2026 Brandywine Consulting Partners · www.brandywine.consulting
Give your next FHIR integration a head start
Bring BCP one source-to-consumer workflow, the mappings you already have and the failure your team keeps revisiting. We identify what is reusable, what needs remediation and how to carry validated mappings, contract tests and ownership into your next integration.